HOME / INSPECTION SERVICES
BUILT AROUND YOUR ASSET
Know what stands between your network and the elements.
Telecom shelter inspections that turn visible conditions
into documented findings and clear maintenance priorities.
INSPECTION FOCUS
One shelter.
Every connection.
01
Accessible shelter and site components
Physical condition
02
Photographs and location-specific findings
Documented evidence
03
A useful baseline for your next decision
Maintenance priorities
STRUCTURE / ENCLOSURE / SUPPORTING SYSTEMS
WHAT WE INSPECT
Six areas. One complete view.
Each inspection is tailored to your shelter, site access, and agreed scope.
We assess accessible physical conditions and document what needs attention.
06
Evidence of deterioration inside and throughout the shelter.
-
Wall/ceiling panels, flooring, insulation, and mountain surfaces
-
Floor and cable penetrations; water staining and moisture damage
-
Condensation, leak indicators, mold-like growth, and seal failures
-
Corrosion documented across systems; moisture-meter readings where included in the agreed scope
Interior, Moisture, & Corrosion
05
Physical condition without disrupting telecom integration.
-
Accessible electrical service, junction boxes, and enclosures
-
Visible wiring, cable penetrations, labeling, and disconnects
-
Grounding/bonding connections; corrosion and damaged components
Electrical Infastructure
04
A visual assessment of accessible mechanical systems.
-
Units, mounts, refrigerant lines, ductwork, filters, and fans/blowers
-
Condensate drains and pans; exterior penetrations and disconnects
-
Visible corrosion, physical damage, and loose components
-
General operating condition where safely observable
HVAC & Mechanical Condition
02
Protection from the elements. Reliable physical access.
-
Roof membrane, seams, joints, flashing, caulking, and sealants
-
Wall joints, cable/conduit penetrations, and window seals where present
-
Doors, frames, hinges, locks, latches, hardware, and weather seals
-
Closure, alignment, emergency exit condition, and water-entry pathways
Exterior, Weatherproofing, & Access
03
The connection between the shelters and its surroundings.
-
Grading, drainage, standing water, erosion, and vegetation
-
Site accessibility and physical damage from vehicles or equipment
-
Trip hazards, sharp edges, loose panels, and unsafe access
-
Visible ladder/platform condition, housekeeping, and fire extinguisher presence and physical condition
Site, Drainage & Safety
01
The shelter and the components that support it.
-
Foundation, mounting system, anchors, and attachment points
-
Frame, supports, floor system, subfloor, walls, and roof structure
-
Settlement, shifting, sagging, deformation, and structural corrosion
-
Visible transport or installation damage; equipment mounts and lifting points where applicable
Structure & Foundation
WHAT HAPPENS NEXT
A record you can use.
A baseline you can revisit.
Every shelter receives a report connection observations
with photographs, locations, and maintenance priorities.
Corrosion findings are classified by severity.
01
Shelter indentification
Site, location, manufacturer/model, approximate age, inspection date, inspector, and customer.
02
1-5 scores for structure, envelope, mechanical, electrical, interior, and foundation/site.
Category condition scores
03
Findings & next steps
Photo documentation, observed conditions, and priorities for maintenance or further evaluation.

